Beckman Acculab 6 Spectrophotometer with open sample compartment
Box 84- 1973 – 1982
The Beckman Instruments IR spectrophotometers began as a request from the Office of Rubber Reserve to Arnold O. Beckman in 1942, asking for an infrared spectrophotometer that they could use to create rubber. Under this…
-
Man using a Beckman Model 915 Total Organic Carbon Analyzer
Box 84- Circa 1968
- Photographer Hesketh, Dean D.
- Subject Scientific apparatus and instruments, Carbon--Analysis, Beckman Instruments, Inc.
-
Beckman Model 915 Total Organic Carbon Analyzer with drawer retracted
Box 84- Circa 1968
The Model 915 converted samples to carbon dioxide and used a non-dispersive infrared analyzer to determine the total carbon and inorganic carbon. Organic carbon was determined as the difference between those values.
- Photographer Hesketh, Dean D.
- Subject Scientific apparatus and instruments, Carbon--Analysis, Beckman Instruments, Inc.
-
Beckman Model 915 Total Organic Carbon Analyzer with drawer pulled out
Box 84- Circa 1968
The Model 915 converted samples to carbon dioxide and used a non-dispersive infrared analyzer to determine the total carbon and inorganic carbon. Organic carbon was determined as the difference between those values.
- Photographer Hesketh, Dean D.
- Subject Scientific apparatus and instruments, Carbon--Analysis, Beckman Instruments, Inc.
-
Man using a Total Hydrocarbon Analyzer beside a car
Box 84- Undated
Beckman Instruments, Inc. became interested in measuring, controlling, and fighting air pollution in the late 1940s and early 1950s, when company president Arnold O. Beckman became the scientific adviser to the Los…
-
Beckman Model 900 pH Analyzer (Interior)
Box 84- Circa 1969
Arnold Beckman invented his first pH meter in 1934 at the request of a chemist from the California citrus industry, who needed an accurate way to measure the acidity of his product. The resulting instrument kicked off…
-
Operator adjusting a dial on Beckman Auto Exhaust Total Hydrocarbon Analyzer
Box 84- Undated
Beckman Instruments, Inc. became interested in measuring, controlling, and fighting air pollution in the late 1940s and early 1950s, when company president Arnold O. Beckman became the scientific adviser to the Los…
-
Beckman Model 900 pH Analyzer (Part)
Box 84- Circa 1969
Arnold Beckman invented his first pH meter in 1934 at the request of a chemist from the California citrus industry, who needed an accurate way to measure the acidity of his product. The resulting instrument kicked off…
-
Beckman Process Panels
Box 84- Undated
- Photographer Dietrich, T. A.
- Subject Scientific apparatus and instruments, Process control, Beckman Instruments, Inc.
-
Man in hard hat examining Beckman process panels
Box 84- Undated
- Photographer Dietrich, T. A.
- Subject Scientific apparatus and instruments, Process control, Beckman Instruments, Inc.
-
-
Helium Ionization Detector
Box 84- 1967
Helium ionization detectors are used in gas chromatography.
Beckman Instruments entered the gas chromatograph business in 1956 with the acquisition of the successful Watts Manufacturing Company. Later that year,…
-
Beckman Industrial Gas Chromatograph
Box 84- 1956 – 1969
Beckman Instruments entered the gas chromatograph business in 1956 with the acquisition of the successful Watts Manufacturing Company. Later that year, Beckman Instruments produced its first gas chromatograph, the GC-1,…
-
Beckman Gas Chromatograph, Series D Analyzer, with open case
Box 84- 1967
Beckman Instruments entered the gas chromatograph business in 1956 with the acquisition of the successful Watts Manufacturing Company. Later that year, Beckman Instruments produced its first gas chromatograph, the GC-1,…
-
Beckman Process Gas Chromatograph, Series E Analyzer, with open case
Box 84- Undated
Beckman Instruments entered the gas chromatograph business in 1956 with the acquisition of the successful Watts Manufacturing Company. Later that year, Beckman Instruments produced its first gas chromatograph, the GC-1,…
-
Beckman Total Hydrocarbon Analyzer
Box 84- Undated
Beckman Instruments, Inc. became interested in measuring, controlling, and fighting air pollution in the late 1940s and early 1950s, when company president Arnold O. Beckman became the scientific adviser to the Los…
-
Beckman IGC Sample Handling System
Box 84- Undated
- Photographer Hesketh, Dean D.
- Subject Scientific apparatus and instruments, Beckman Instruments, Inc.
-
Beckman Model 82
Box 84- Undated
- Photographer Laursen, Rene
- Subject Scientific apparatus and instruments, Beckman Instruments, Inc.
-
Beckman Model 735 Dissolved O2 Analyzer
Box 84- Circa 1968
Developed from a Linus Pauling design during WWII, the technology behind Beckman Instruments’ oxygen analyzers ended up doing such diverse jobs as monitoring astronauts’ respiration, maintaining packaged food safety,…
-
Beckman Model 762 Dissolved O2 Analyzer
Box 84- 1954 – 1969
Developed from a Linus Pauling design during WWII, the technology behind Beckman Instruments’ oxygen analyzers ended up doing such diverse jobs as monitoring astronauts’ respiration, maintaining packaged food safety,…
-
-
Beckman Model 82 Data Processor with Scott Cart
Box 84- Undated
- Photographer Laursen, Rene
- Subject Electronic data processing, Scientific apparatus and instruments, Beckman Instruments, Inc.
-
Beckman Vehicle Emissions Analyzer
Box 84- Undated
This instrument detects pollutants in the emissions from vehicles with combustion engines.
Beckman Instruments, Inc. became interested in measuring, controlling, and fighting air pollution in the late 1940s and early…
-
Beckman Model 906 SO2 Analyzer
Box 84- 1960s
Beckman Instruments, Inc. became interested in measuring, controlling, and fighting air pollution in the late 1940s and early 1950s, when company president Arnold O. Beckman became the scientific adviser to the Los…
-