Beckman Biogamma II Counting System
- 1975 – 1984
Beckman's Biogamma II was introduced in 1975. Radioimmunoassay (RIA) is a technique for measuring the antigen concentration. Known quantities of radioactive (labeled or “hot”) antigens and antibodies are mixed, then…
-
Beckman Glucose Analyzer 2
- Circa 1979
The Glucose Analyzer was developed by James Sternberg in 1969 and was one of several very successful medical testing and analysis instruments that Beckman Instruments produced in the 1970s. Its size, speed, and price…
-
Beckman Creatinine Analyzer 2
- Circa 1979
Beckman's Creatinine Analyzer 2 debuted in 1979. Creatinine, a byproduct of muscle metabolism, can be measured to determine renal function.
-
Beckman Cl/CO2 Analyzer
- 1975 – 1984
Beckman first marketed a chloride/CO2 analyzer in 1975.
The instrument simultaneously measured chloride and carbon dioxide. It was used in clinical settings to analyze serum, spinal fluid, and sweat.
-
Beckman Accutrace 16 Electroencephalograph
- 1973 – 1982
The Beckman Accutrace was introduced in 1973. Electroencephalographs are used to monitor and record electrical activity of the brain.
-
Beckman BUN, Creatinine, and Glucose Analyzers
- 1979 – 1988
BUN stands for Blood Urea Nitrogen.
Creatinine, a byproduct of muscle metabolism, can be measured to determine renal function.
The Glucose Analyzer was developed by James Sternberg in 1969 and was one of several very…
-
Beckman KLiNa Flame System and a Cl/CO2 Analyzer
- 1975 – 1984
Beckman introduced the KLiNa Flame System, a flame photometer with attached diluter and printer, in 1971. The company first marketed a chloride/CO2 analyzer in 1975.
Flame photometers determine the presence and…
-
Beckman System 1 Glucose/BUN Analyzer
- 1974 – 1983
This instrument, introduced in 1974, can run both blood glucose and blood urea nitrogen (BUN) analyses.
The Glucose Analyzer was developed by James Sternberg in 1969 and was one of several very successful medical…
-
Beckman Accutrace Electroencephalograph
- 1973 – 1982
The Beckman Accutrace was introduced in 1973. Electroencephalographs are used to monitor and record electrical activity of the brain.
-
Masked man with a rabbit and a Beckman TOXSYS Terminal
- 1978 – 1984
An unidentified man in a lab coat and mask gets toxicology readings of a rabbit using a TOXSYS Terminal. The cages in the background likely hold other animals intended for testing. This toxicology instrument uses…
-
Man with breathing apparatus and electrodes of Beckman MMC Horizon System
- 1975 – 1984
Beckman Instruments introduced the Metabolic Measurement Cart (MMC) in 1975. The programmable system could automatically test oxygen, carbon dioxide, barometric pressure, expired air volume and temperature, and print…
-
Beckman MMC Horizon System
- 1975 – 1984
Beckman Instruments introduced the Metabolic Measurement Cart (MMC) in 1975. The programmable system could automatically test oxygen, carbon dioxide, barometric pressure, expired air volume and temperature, and print…
-
Beckman System TR Enzyme Activity Analyzer
- 1973 – 1982
Beckman’s System TR, introduced in 1973, was the first automated analyzer for clinical enzymes.
-
Beckman Enzyme Activity Analyzer System TR
- 1973 – 1982
Beckman’s System TR, introduced in 1973, was the first automated analyzer for clinical enzymes.
-
Beckman Cl/CO2 Analyzer
- 1975 – 1984
Beckman first marketed a chloride/CO2 analyzer in 1975.
The instrument simultaneously measured chloride and carbon dioxide. It was used in clinical settings to analyze serum, spinal fluid, and sweat.
-
Beckman System 1 Glucose/BUN Analyzer
- 1974 – 1989
This instrument, introduced in 1974, can run both blood glucose and blood urea nitrogen (BUN) analyses.
The Glucose Analyzer was developed by James Sternberg in 1969 and was one of several very successful medical…
-
Woman using Beckman Glucose Analyzer and BUN Analyzer
- 1970s
An unidentified woman in a laboratory works in front of a bench holding a Beckman Glucose Analyzer and a Beckman BUN (Blood Urea Nitrogen) Analyzer.
The Glucose Analyzer was developed by James Sternberg in 1969 and…
-
Beckman TOXSYS Terminal
- 1978 – 1984
TOXSYS software facilitates the chemical analysis of body tissues.
-
Beckman TOXSYS and other equipment
- 1978 – 1984
Medical books and a microscope sit on a desk beside a Beckman TOXSYS terminal. The TOXSYS software facilitates the chemical analysis of body tissues.
- Photographer Karjalas' Photo Vision
- Subject Scientific apparatus and instruments, Toxicology, Beckman Instruments, Inc.
-
Beckman/Spinco Model 121M Microcolumn Amino Acid Analyzer
- 1973 – 1982
First marketed in 1960, the Beckman/Spinco Model 120 Amino Acid Analyzer allowed users to quickly perform amino acid chromatography. The Model 121M Microcolumn Amino Acid Analyzer was released in 1973.
-
Close-up of dials on a Spinco Model 121 Amino Acid Analyzer
- 1969 – 1978
First marketed in 1960, the Beckman/Spinco Model 120 Amino Acid Analyzer used the Spackman-Stein-Moore technique of amino acid chromatography. The Model 121, which debuted in the late 1960s, does the same process, but…
-
Beckman Model 121 Amino Acid Analyzer and a lab coat draped over an empty chair
- 1969 – 1978
First marketed in 1960, the Beckman/Spinco Model 120 Amino Acid Analyzer used the Spackman-Stein-Moore technique of amino acid chromatography. The Model 121, which debuted in the late 1960s, does the same process, but…
-
Beckman Model 121-C Amino Acid Analyzer
- 1969 – 1978
First marketed in 1960, the Beckman/Spinco Model 120 Amino Acid Analyzer used the Spackman-Stein-Moore technique of amino acid chromatography. The Model 121, which debuted in the late 1960s, does the same process, but…
-
Beckman/Spinco Model 121-M Amino Acid Analyzer
- 1969 – 1978
First marketed in 1960, the Beckman/Spinco Model 120 Amino Acid Analyzer used the Spackman-Stein-Moore technique of amino acid chromatography. The Model 121, which debuted in the late 1960s, does the same process, but…
-
Beckman Accutrace Electroencephalograph
- 1973 – 1982
The Beckman Accutrace was introduced in 1973. Electroencephalographs are used to monitor and record electrical activity of the brain.