Diagram related to Bendix Time-of-Flight Mass Spectrometer
- 1960s
Schematic diagram comparing the time-of-flight of an ion to its initial position in a Bendix Time-of-Flight Mass Spectromter. Time-of-flight mass spectrometry (TOFMS) is a method of mass spectrometry in which an ion's…
-
Diagram of Bendix Model 843T Thermal Ionization Probe
- 1960s
Schematic diagram of a Bendix Model 843T Thermal Ionization Probe designed for use with the Bendix Time-of-Flight Mass Spectrometer. This surface ionization inlet system provided a means of creating ions for spectral…
-
Diagram depicting total output integrator time sequence
- 1960s
Schematic diagram depicting the total output integrator time sequence of a Bendix Corporation Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the…
-
Diagram depicting energy focusing in Bendix Mass Spectrometer
- 1960s
Schematic diagram depicting energy focusing in a Bendix Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation.
Mass spectrometry…
-
Diagram depicting background spectrum reading for Bendix Mass Spectrometer
- 1960s
Schematic diagram depicting the typical background spectrum reading for a Bendix Time-of-Flight Mass Spectrometer with a thermal ionization probe in place. As part of the Bendix system, the thermal ionization probe…
-
Diagram depicting air spectrum on scope
- 1960s
Diagram depicting air spectrum on scope, showing readings for nitrogen gas, oxygen, and carbon dioxide. This diagram is likely the output of a Bendix Corporation Time-of-Flight Mass Spectrometer, an instrument commonly…
- Creator Of Work Bendix Corporation
- Subject Scientific apparatus and instruments, Spectrometer industry, Mass spectrometry, Bendix Corporation
-
Control panel for Bendix Mass Spectrometer
- 1960s
Close-up view of the control panel of a Bendix MA-2 Time-of-Flight Mass Spectrometer, with view of various components including the oscilloscope trace offset controller, cycle trigger, and output integrator. The…
-
2 items
Components of Bendix Model 843A Direct Inlet System
- 1960s
Two close-up views of the filament and crucible of a Bendix Model 843A Direct Inlet System. Inlet systems are typically used to introduce samples into a mass spectrometer's ion source for analysis. The Model 843A Direct…
- Creator Of Work Bendix Corporation
- Subject Scientific apparatus and instruments, Spectrometer industry, Mass spectrometry, Bendix Corporation
-
Component of Bendix Mass Spectrometer
- 1960s
Close-up view of a component part, possibly a filament, of a Bendix Time-of-Flight Mass Spectrometer. A Fisher Scientific ruler is visible next to the component to indicate its size. The Time-of-Flight Mass Spectrometer…
-
Chart recorder for Bendix Mass Spectrometer
- 1960s
General view of the back of a chart recorder for a Bendix Corporation Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation.
… -
Bendix employee with assorted scientific instruments
- 1960s
General view of an unidentified Bendix Corporation employee surrounded by assorted scientific instruments from a range of companies, including Bendix, Varian, and DuMont. Per an inscription on the verso of the…
- Creator Of Work Bendix Corporation
- Subject Employees, Scientific apparatus and instruments, Spectrometer industry, Mass spectrometry, Bendix Corporation
-
Bendix Time-of-Flight Mass Analyzer
- 1960s
Close-up view of the control panel for a Bendix Corporation Time-of-Flight Mass Analyzer. One of four component parts of a mass spectrometer, the mass analyzer is used to separate the particles of a sample material…
-
Bendix RGA-1A Time-of-Flight Residual Gas Analyzer with female model
- 1960s
General view of a Bendix RGA-1A Time-of-Flight Residual Gas Analyzer with female model. The Bendix RGA-1 was specifically designed and marketed to enable accurate determination of the total pressure of a vacuum chamber…
-
Bendix Model 843A Direct Inlet System
- 1960s
Diagram of a Bendix Corporation Model 843A Direct Inlet System with view of assorted component parts, including a crucible, filament, vacuum system header, and sample probe. Inlet systems are typically used to introduce…
- Creator Of Work Bendix Corporation
- Subject Scientific apparatus and instruments, Spectrometer industry, Mass spectrometry, Bendix Corporation
-
5 items
Bendix Model 1030 Knudsen Cell Inlet System
- 1960s
Multiple views of the interior and exterior of the Bendix Model 1030 Knudsen Cell Inlet System. Inlet systems are typically used to introduce samples into a mass spectrometer's ion source for analysis. The Knudsen Cell…
-
Bendix Mass Spectroscopy handling system
- 1960s
Promotional display depicting the Bendix Corporation Mass Spectroscopy handling system. One of four component parts of a mass spectrometer, the handling system is used to introduce an unknown substance into the…
-
Bendix Magnetic Electron Multiplier
- 1960s
Close-up view of a Bendix Corporation Magnetic Electron Multiplier designed for use with the Bendix Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument…
-
Bendix MA-2 Time-of-Flight Mass Spectrometer with female model
- 1960s
General view of a Bendix MA-2 Time-of-Flight Mass Spectrometer with a female model. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation.
Mass spectrometry is an…
-
2 items
Bendix MA-2 Time-of-Flight Mass Spectrometer prototype
- 1960s – circa
Two views of a prototype of the Bendix MA-2 Time-of-Flight Mass Spectrometer, with a close-up of assorted control panels showing controls for the ionization gauge, inlet system pumping valve, thermocouple station, and…
-
Bendix MA-2 Time-of-Flight Mass Spectrometer
- 1960s
General view of a Bendix MA-2 Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation.
Mass spectrometry is an analytical…
-
Bendix MA-2 Time-of-Flight Mass Spectrometer
- 1960s
General view of a Bendix MA-2 Time-of-Flight Mass Spectrometer system. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation.
Mass spectrometry is an analytical…
-
2 items
Bendix MA-2 Time-of-Flight Mass Spectrometer
- 1960s
Two views of a Bendix MA-2 Time-of-Flight Mass Spectrometer. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation.
Mass spectrometry is an analytical technique…
-
4 items
Bendix MA-1A Time-of-Flight Mass Spectrometer
- 1960s
Series of photographs depicting the Bendix MA-1A Time-of-Flight Mass Spectrometer and a female model. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical instrument of the Bendix Corporation.
Mass…
-
2 items
Bendix MA-1 Time-of-Flight Mass Spectrometer
- 1960s
Two views of the Bendix Corporation's MA-1 Time-of-Flight Mass Spectrometer, with view of the vacuum system and main electronics console. The Time-of-Flight Mass Spectrometer (TOFMS) was the flagship analytical…
-
Bendix Knudsen Cell Inlet System
- 1960s
Interior view of the power supply of a Bendix Corporation Knudsen Cell Inlet System. Inlet systems are typically used to introduce samples into a mass spectrometer's ion source for analysis. The Knudsen Cell Inlet…